Connection Information

To perform the requested action, WordPress needs to access your web server. Please enter your FTP credentials to proceed. If you do not remember your credentials, you should contact your web host.

Connection Type

Header section – PB Docs 126 – PowerBuilder Library

Header section – PB Docs 126

Header section

The Header section can contain the items listed in Table 6-12. Only the root XHTML <form> element
is required:

Table 6-12: Items permitted in the Header
section of an XHTML document

Item

Details

Root <form> element (start
tag)

The XHTML <form> element
is the root element of the XHTML template. See “Root element”.

XHTML elements

Additional elements below the root element.

DataWindow control references

Text. See “DataWindow controls”.

DataWindow expressions

Text. See “DataWindow expressions”.

Literal text

Text that does not correspond to a DW
control.

Attributes

Can be assigned to all elements. See “Element attributes”.

CDATA sections

See “CDATA sections”.

Child elements

Child elements in the Header section
cannot be iterative except for the Group DataWindow.

note.png Detail section in root element

The root element displays in the Header section, but the entire
content of the Detail section is contained in the root element.

The items in the Header section are generated only once at
runtime (when the DataWindow is exported to XHTML), unless the DataWindow
is a Group DataWindow. For Group DataWindows, the corresponding
XHTML fragment in the Header section is repeated so that it iteratively
heads each group detail—the group of XHTML rows corresponding
to the group specified in the DataWindow.

The Header section contains the rendering of the DataWindow
header band and any group header bands. Bands are generated within <div> elements.
The controls rendered in the Header section (such as computed titles
and text control column headings) are typically also generated within <div> elements, with
referenced content.

These entities are generated only once and are not iterated
for each row. However, for DataWindows with group headers, the corresponding
XHTML fragment in the Header section is repeated, iteratively heading
each group of XHTML rows corresponding to the group specified in
the DataWindow.


Document get from Powerbuilder help
Thank you for watching.
Was this article helpful?
Subscribe
Notify of
guest
0 Comments
Oldest
Newest Most Voted
Inline Feedbacks
View all comments
0
Would love your thoughts, please comment.x
()
x