Connection Information

To perform the requested action, WordPress needs to access your web server. Please enter your FTP credentials to proceed. If you do not remember your credentials, you should contact your web host.

Connection Type

TimeStamp – PB Docs 2022 – PowerBuilder Library

TimeStamp – PB Docs 2022

TimeStamp

database parameter

Description

Specifies whether PowerBuilder should map DateTime and Time
datatypes to the Oracle TimeStamp datatype.

Applies to

OLE DB

O90 Oracle9i

O10 Oracle 10g

ORA Oracle (for 11g and later)

SQLNCLI10

Syntax

Parameter

Description

value

Specifies whether PowerBuilder should map DateTime
and Time datatypes to the Oracle TimeStamp datatype. Values
are:

  • 0

    Map DateTime and Time datatypes to the Oracle Date
    datatype.

  • 1

    (Default) Map DateTime and Time datatypes to the
    Oracle TimeStamp datatype.

Default value

TimeStamp=1

Usage

Oracle9i and later databases and the O90 and O10 interfaces
support the Oracle timestamp datatype. This datatype includes the date
and the time including milliseconds. The existing Oracle Date datatype
does not include millisecond information. In a DataWindow object, both
the Oracle Timestamp and Date datatypes are mapped to the PowerBuilder
DateTime datatype, which supports millisecond information.

If you use the O90 or O10 interface with an Oracle9i or higher
server, DateTime and Time datatypes are mapped to the Oracle TimeStamp
datatype by default. If you want DateTime and Time to be mapped to the
Oracle Date datatype, set the TimeStamp database parameter to 0.

In PowerBuilder 8 and earlier, millisecond information was
truncated when used with the Oracle Date datatype. In PowerBuilder 9.0
and later, millisecond information is not truncated. As a result, when
performing multiple updates to a DateTime field that maps to a Date
column, the first update succeeds, but subsequent updates fail with a
“row changed between retrieve and update error”.

If you are using an interface with a database that uses only the
TimeStamp datatype, PowerBuilder handles updates correctly. If the
database uses the Oracle Date datatype only, set the DBParm TimeStamp to
0 to truncate millisecond information.

If you are using a database that uses both Date and TimeStamp
datatypes, you must determine which columns use each datatype, and strip
the milliseconds from the Date columns using code like the
following:

Examples

To set the TimeStamp value to treat DateTime and Time DataWindow
datatypes as Oracle Date datatypes:

  • Database profile

    Clear the Map DateTime/Time to Oracle Timestamp check box on
    the Syntax page in the Database Profile Setup dialog box.

  • Application

    Type the following in code:


Document get from Powerbuilder help
Thank you for watching.
Was this article helpful?
Subscribe
Notify of
guest
0 Comments
Oldest
Newest Most Voted
Inline Feedbacks
View all comments
0
Would love your thoughts, please comment.x
()
x