StaticBind – PB Docs 2019 – PowerBuilder Library

StaticBind – PB Docs 2019

StaticBind

database parameter

Description

When you retrieve data from a database into a DataWindow object or
report, PowerBuilder does not get a result set description to validate
the SELECT statement against the database server before retrieving the
data. This means the retrieval should be faster, especially when you are
accessing the database over a network. (This feature is called
describeless retrieval.)

If you want to override the default behavior and have PowerBuilder
get a description of the result set before retrieving data, set the
StaticBind parameter to 0 or No.

Applies to

ADO.NET

ASE and SYC SAP Adaptive Server Enterprise

DIR SAP DirectConnect

JDB JDBC

ODBC

OLE DB

O90 Oracle9i

O10 Oracle 10g

ORA Oracle (for 11g and later)

SNC SQL Native Client for Microsoft SQL Server

MSOLEDBSQL Microsoft OLE DB Driver for SQL Server

Syntax

Parameter

Description

value

Specifies whether you want PowerBuilder to get a
result set description before retrieving data from a database
into a DataWindow object or report. Values
are:

  • 0

    Get a result set description before retrieving data.
    You can also specify ‘No’ to set this value.

  • 1

    (Default) Skip getting a result set description
    before retrieving data. You can also specify ‘Yes’ to set
    this value.

Default value

StaticBind=1

Usage

Validation

When StaticBind is set to 1 (the default), PowerBuilder does not
validate the SELECT statement against the database server before
retrieving data. It assumes that the result set matches the column
format of the DataWindow object or report into which it is being
retrieved. If a mismatch occurs, PowerBuilder displays an error.

Troubleshooting tips

Problems can occur in your application if the result set
description obtained by the DataWindow object or report is different
from the current database description of the result set. This can occur
for the following reasons:

  • The database definition changes after you build the DataWindow
    object or report.

  • You build the DataWindow object or report while connected to
    one DBMS and then run it against a different DBMS.

To fix problems caused by conflicting result set descriptions, you
can correct your DataWindow object or report definition by doing either
of the following:

If your DataWindow object or report and DBMS result set
descriptions do not match and you want to avoid errors, set StaticBind
to 0 or No to specify that PowerBuilder should always get a result set
description before retrieving data into a DataWindow object or
report.

Examples

To specify that you want PowerBuilder to get a result set
description before retrieving data into a DataWindow object or
report:

  • Database profile

    Clear the Static Bind check box on the Transaction page (or
    System page in the case of the OLE DB interface) in the Database
    Profile Setup dialog box.

  • Application

    To specify this statement in code, type the following:


Document get from Powerbuilder help
Thank you for watching.
Was this article helpful?
Subscribe
Notify of
guest
0 Comments
Oldest
Newest Most Voted
Inline Feedbacks
View all comments
0
Would love your thoughts, please comment.x
()
x