Requirements for using Open Client security services

For you to use Open Client security services in your application,
all of the following must be true:

  • You are accessing an Adaptive Server database server using
    Open Client Client-Library (CT-Lib) 11.1.x or later software.

  • You have the required network security mechanism and
    driver.

    You have the required SAP-supported network security mechanism
    and SAP-supplied security driver properly installed and configured
    for your environment. Depending on your operating system platform,
    examples of supported security mechanisms include: Distributed
    Computing Environment (DCE) security servers and clients, CyberSafe
    Kerberos, and Windows NT LAN Manager Security Services Provider
    Interface (SSPI).

    For information about the third-party security mechanisms and
    operating system platforms that Appeon has tested with Open Client
    security services, see the Open Client documentation.

  • You can access the secure server outside PowerBuilder.

    You must be able to access a secure Adaptive Server server
    using Open Client 11.1.x or later software from outside
    PowerBuilder.

    To verify the connection, use a tool such as ISQL or
    SQL Advantage to make sure you can connect to the server and log in
    to the database with the same connection parameters and security
    options you plan to use in your PowerBuilder application.

  • You are using a PowerBuilder database interface.

    You are using the ASE or SYC Adaptive Server interface to
    access the database.

  • The Release DBParm parameter is set to the appropriate value
    for your database.

    You have set the Release DBParm parameter to 11 or higher to
    specify that your application should use the appropriate version of
    the Open Client CT-Lib software.

    For instructions, see Release in the section called “Release” in Connection Reference.

  • Your security mechanism and driver support the requested
    service.

    The security mechanism and driver you are using must support
    the service requested by the DBParm parameter.


Document get from Powerbuilder help