OraMTSConFlgs (obsolete) – PB Docs 2022

OraMTSConFlgs (obsolete)

Description

Specifies the behavior of a transactional PowerBuilder component
deployed to COM+. This parameter applies only when a PowerBuilder custom
class user object is deployed as a COM+ component and is connecting to
an Oracle 8.1.5 or higher database.

Obsolete DBParm

You can no longer deploy components from PowerBuilder to COM+
servers. The OraMTSConFlgs DBParm is maintained for backward
compatibility to existing PowerBuilder components on COM+ servers. For
new development, deploy components as .NET projects instead.

Applies to

O90 Oracle9i

O10 Oracle 10g

ORA Oracle (for 11g and later)

Syntax

Parameter

Description

value

Specifies the behavior of a transactional component
deployed to COM+. Values are:

  • All Default

    (Default) Obtains a pooled connection and enlists
    the connection in any COM+ transaction, if one exists
    (ORAMTS_CFLG_ALLDEFAULT).

  • No Implicit Enlistment

    Obtains a pooled connection but does not enlist the
    resource in any COM+ transaction even if the component is
    transactional (ORAMTS_CFLG_NOIMPLICIT).

  • Unique Server Session

    Requests a single OCI session per OCI Server. Since
    multiplexing is not supported in Version 8.1.5, this
    option is always used (ORAMTS_CFLG_UNIQUESRVR).

  • SYSDBA Login

    Required if connecting as SYSDBA
    (ORAMTS_CFLG_SYSDBALOGN).

  • SYSOPER Login

    Required if connecting as SYSOPER
    (ORAMTS_CFLG_SYSOPRLOGN).

  • Preliminary INTERNAL Login

    Required if connecting as INTERNAL
    (ORAMTS_CFLG_PRELIMAUTH).

Default value

OraMTSConFlgs=’ORAMTS_CFLG_ALLDEFAULT’

Usage

If a transactional PowerBuilder component deployed to COM+ uses a
PowerBuilder native interface to connect to an Oracle 8.1.5 or higher
database, COM+ attempts to obtain a pooled connection and enlist the
connection in a transaction. You can specify different behavior by
selecting one or more of the available options.

When the Oracle database interface is running under COM+,
ThreadSafe mode is enabled by default and the value of the ThreadSafe
parameter is ignored.

This parameter cannot be set dynamically. The value set when the
connection is made remains in effect until it is disconnected.

These values are not mutually exclusive. They are chained using
the pipe character in the parameter.

Requirements for COM+ transactional support

Oracle Services for COM+ must be installed and
configured.

Examples

To obtain an enlisted connection using the INTERNAL
account:

  • Application

    Type the following in code (use | to signify a logical OR of
    the flags):


Document get from Powerbuilder help