Connection Information

To perform the requested action, WordPress needs to access your web server. Please enter your FTP credentials to proceed. If you do not remember your credentials, you should contact your web host.

Connection Type

Optimizing expressions for DataWindow and external objects – PB Docs 2022 – PowerBuilder Library

Optimizing expressions for DataWindow and external objects – PB Docs 2022

Optimizing
expressions for DataWindow and external objects

No compiler validation for container
objects

When you use dot notation to refer to a DataWindow object in a
DataWindow control or DataStore, the compiler does not check the validity
of the expression:

Everything you specify after the Object property passes the compiler
and is checked during execution.

The same applies to external OLE objects. No checking occurs until
execution:

Establishing partial
references

Because of the runtime syntax checking, using many expressions like
these can impact performance. To improve efficiency when you refer
repeatedly to the same DataWindow component object or external object, you
can define a variable of the appropriate type and assign a partial
reference to the variable. The script evaluates most of the reference only
once and reuses it.

The datatype of a DataWindow component object is DWObject:

The datatype of a partially resolved automation expression is
OLEObject:

Handling errors

The Error and (for automation) ExternalException events are
triggered when errors occur in evaluating the DataWindow and OLE
expressions. If you write a script for these events, you can catch an
error before it triggers the SystemError event. These events allow you to
ignore an error or substitute an appropriate value. However, you must be
careful to avoid setting up conditions that cause another error. You can
also use try-catch blocks to handle exceptions as described in Exception handling in
PowerBuilder
.

For information

For information about DataWindow data expressions and property
expressions and DWObject variables, see the section called “About
DataWindow data expressions”
in DataWindow Reference, the section called “PowerBuilder:
DataWindow property expressions”
in DataWindow Reference, and
the section called “Using the DWObject variable in
PowerBuilder”
in DataWindow Reference. For information about using
OLEObject variables in automation, see Using OLE in an
Application
.


Document get from Powerbuilder help
Thank you for watching.
Was this article helpful?
Subscribe
Notify of
guest
0 Comments
Oldest
Newest Most Voted
Inline Feedbacks
View all comments
0
Would love your thoughts, please comment.x
()
x