Executing Informix Stored Procedure results in “Numeric value out
of range” error message
Symptom
Running a stored procedure with bind variables results in the
following error:
PowerBuilder ODBC trace:
|
1 2 |
(4a76048): *** ERROR -11025 ***(rc -1) : SQLSTATE = 22003 [Informix][Informix ODBC Driver]Numeric value out of range. |
ODBC Trace log:
|
1 |
DIAG [22003] [Informix][Informix ODBC Driver]Numeric value out of range. (-11025) |
Environment
PowerBuilder
Informix 9
Informix SDK 2.8.0
Informix ODBC Driver 3.8.1
Cause
The problem was caused by running the Informix 2.8.0 SDK which is
not supported in PowerBuilder.
Solution
Upgrading to the Informix 2.8.1 SDK which contains the Informix
3.8.2 ODBC driver resolves the issue.
Document get from Powerbuilder help
Thank you for watching.
Subscribe
Login
0 Comments