BindSPInput

database parameter

Description

Specifies that PowerBuilder bind input parameters in dynamic SQL
statements when executing a stored procedure.

Applies to

ADO.NET

O90 Oracle9i

O10 Oracle 10g

SNC SQL Native Client for Microsoft SQL Server

MSOLEDBSQL Microsoft OLE DB Driver for SQL Server

Syntax

Parameter

Description

value

Specifies whether you want to bind input parameters
in dynamic SQL statements when executing stored procedures.
Values are:

  • 0

    (Default) PowerBuilder does not bind parameters in
    dynamic SQL statements when executing stored
    procedures.

  • 1

    PowerBuilder binds parameters in dynamic SQL
    statements when executing stored procedures.

Default value

BindSPInput=0

Usage

For SNC, when BindSPInput is set to 0, you can use the same syntax
to declare a stored procedure in a script as you can when using the
PowerBuilder OLE DB interface. When BindSPInput is set to 1, the SNC
interface supports SQL Server large value datatypes as procedure IN/OUT
parameters or function return values.

The syntax for declaring a procedure with SNC is:

[@rc=] indicates that you want to get the procedure’s return
value.

Use the keyword OUTPUT or OUT to indicate an output parameter if
you want to get the output parameter’s value.

If BindSPInput=0, value1, value2,… can be either PowerBuilder
script variables or literal values. If BindSPInput=1, value1, value2,…
must be PowerBuilder script variables. If you specify literal values,
the interface returns a runtime error.

When you declare a dynamic SQL statement with a procedure, enter a
question mark (?) for each IN/OUT parameter in the statement. Value
substitution is positional. For examples, see Dynamic SQL Format 3 and 4
in the section called “Using
dynamic SQL”
in PowerScript Reference.

For Oracle, set BindSPInput to 1 to ensure that CLOB, NCLOB, and
BLOB parameters work correctly as stored procedure parameters.

For ADO.NET:

  • When BindSPInput is set to 1, parameter values must be
    PowerBuilder script variables, not literal values.

  • The IBM.Data.Informix driver (used to access an ADO.NET
    compliant Informix database) does not support the BindSPInput
    dbparm.

  • The ADO.NET Microsoft SQL Server interface does not support
    Text, NText, or Image parameters. Use VarChar(max) or VarBinary(max)
    instead.

Examples

Setting BindSPInput

To specify that PowerBuilder should bind parameters in dynamic SQL
statements when executing a stored procedure:

  • Database profile

    Select the Bind Procedure Parameters check box on the
    Transaction page in the Database Profile Setup dialog box.

  • Application

    Type the following in code:

Using the ADO.NET SQL Server interface

Consider the following two SQL statement fragments:

The preceding statement does not work if BindSPInput is set to 1,
because the SQL Server interface does not support Text.

The preceding statement can work with BindSPInput set to 1,
because the SQL Server interface does support VARCHAR(MAX).