Fine-tuning performance for batched source control requests

PowerBuilder uses
an array of object file names that it passes to a source control
system in each of its SCC API requests. The SCC specification does
not mention an upper limit to the number of files that can be passed
in each request, but the default implementation in PowerBuilder
limits SCC server requests to batches of 25 objects.

A PB.INI file setting allows you to override
the 25-file limit on file names sent to the source control server
in a batched request. You can make this change in the Library section
of the PB.INI file by adding the following
instruction:

where nn is
the number of files you want PowerBuilder to include in its SCC API
batch calls. Like other settings in the PB.INI file,
the SccMaxArraySize parameter is not case sensitive.