Connection Information

To perform the requested action, WordPress needs to access your web server. Please enter your FTP credentials to proceed. If you do not remember your credentials, you should contact your web host.

Connection Type

Deploying DataWindow objects to the component server – PB Docs 100 – PowerBuilder Library

Deploying DataWindow objects to the component server – PB Docs 100

Deploying DataWindow objects to the component server

When you run a Web
DataWindow application, the definitions of your DataWindow objects
must be available on the component server. You can ensure this by
copying the PBL or PBD file that contains the definition of the objects
to the server. If you are using EAServer,
the files must be in the server’s path, or if the server
component is running as a service, in the system path. COM+ always
runs as a service, so the files must be in the COM+ server’s system
path.

For more information about setting up your development environment,
see “Server configuration requirements”.

The Web DataWindow Container project wizard

In PowerBuilder, you can use the Web DataWindow Container
project wizard to create a project that deploys a custom version
of the Web DataWindow server component (HTMLGenerator90) to EAServer with all the DataWindow
objects in your library list built into the deployed PBD.

Because you are using a custom component instead of the preinstalled HTMLGenerator90 component,
you can set properties for your component in EAServer Manager.
Setting properties reduces the number of method calls required to
configure the component and can result in improved performance, maintainability,
and scalability.

Using the wizard

When you have defined the DataWindow objects you need, start
the Web DataWindow Container wizard from the Project page of the
New dialog box and follow the instructions in the wizard.

The choices you make in the wizard are similar to those you
make for other EAServer components,
such as whether to support instance pooling or live editing. The
package and component can have any names you want, with the exception
that you cannot name the package DataWindow (the
name of the package that contains the preinstalled HTMLGenerator90 component).
You cannot set component type or transaction support properties.

Building the Web DataWindow Container project presets some
of the properties of the component that you would otherwise need
to set in scripts or in EAServer Manager.
You can specify a database profile in the wizard or Project painter
to set the com.sybase.datawindow.trans.dbms and other database transaction
properties. If you want calls to component methods to be written
to the server log, select Enable Trace to set the com.sybase.datawindow.trace
property.

note.gif Connection cache Specifying a profile sets database transaction properties
for the component, but you still need to create a connection cache
in EAServer Manager for the database
the component will access.

Service classes

You can add a custom class user object to your project to
perform any special processing you require. This object acts as
a service class. The custom class user object must be in the same
library as the DataWindow objects or on the target’s library
list. When you build the Web DataWindow Container project, select
the class in the Select Objects dialog box in the Project painter.

For more information, see “Using service classes”.

Instantiating the container component

When you create an instance of the container component, you
must either provide a Java proxy for the component or pass DataWindow/HTMLGenerator90 as
the last argument to the CreateComponent method. This specifies
that the component uses the proxy provided for the generic component.
For example:

This is the same way you instantiate custom components. For
more information on custom components, see “Instantiating the custom
component”
.

Selecting a DataWindow from the container component

To select a DataWindow from the container component, you must
use the SetDWObjectEx method rather than the SetDWObject method:

For more information on the SetDWObject method, see “Loading the DataWindow object” and the DataWindow
Reference

.

Using the component with the Web DataWindow DTC

You can select the container component when you use the Web/JSP DataWindow
Page wizard to create a new Web page. On the Choose EAServer Profile page in the wizard,
check the Use Custom Web DW Component check box. Then, when you
click Next, the wizard prompts you for the component name and the
DataWindow in the component that you want to include on your Web
page.

On the DataWindow page of the Web DataWindow DTC property
sheet, you can also specify a container component and the DataWindow
in the container component that you want to use on a Web page. Selecting
a container component on the DataWindow page automatically selects
it on the HTML Generator page of the DTC property sheet. (If you
want, it is possible just to use the container component to generate
XHTML or HTML for a DataWindow that you select from a PBL, PSR,
or SRD file).

proc.gif To use the container component with the Web DataWindow
DTC

  1. Select the Web DataWindow Container Component
    radio button on the DataWindow page of the Web DataWindow DTC property
    sheet.

  2. Click the browse button (…) next to the Component
    text box.

    The Web DataWindow Container Component dialog box displays.
    It has a list box with nodes for each EAServer profile
    defined in PowerBuilder.

  3. Expand the node for the server and package that
    contains the container component you want to use.

    Select the container component and click OK.

    The Web DataWindow DTC property sheet redisplays. The server
    name and the container package and component are displayed in the
    Server and Component text boxes on the DataWindow page of the property
    sheet.

  4. Select a DataWindow from the DataWindow drop-down
    list.

    The drop-down list displays all the DataWindows in the container component.

  5. (Optional) Click the Connection tab and override
    the database connection property stored by the component.

    This is recommended only for testing purposes. If you want
    to change the connection property, you can do it directly from EAServer Manager.

  6. (Optional) Click the Control tab and override
    the weight settings stored with the DataWindow.

  7. Click OK.


Document get from Powerbuilder help
Thank you for watching.
Was this article helpful?
Subscribe
Notify of
guest
0 Comments
Oldest
Newest Most Voted
Inline Feedbacks
View all comments
0
Would love your thoughts, please comment.x
()
x