Connection Information

To perform the requested action, WordPress needs to access your web server. Please enter your FTP credentials to proceed. If you do not remember your credentials, you should contact your web host.

Connection Type

Browser Error Messages – PB Docs 120 – PowerBuilder Library

Browser Error Messages – PB Docs 120


Browser Error Messages

Runtime errors for Web Forms applications are often posted in the client browser.

Null reference exception

The �Object reference not set to an instance of an object� error
message might display in a client browser for a Web Forms application
if the application uses an unsupported version of the .NET Framework.
The error message description indicates that �an unhandled exception
occurred during the execution of the current web request,� and
the exception details display a �System.NullReferenceException�.

You can resolve this type of error by opening a command window
on the server, changing directories to the Microsoft.NETFrameworkv2.0.50727
directory in the Windows system path, and typing the following command: aspnet_regiis
-i
. This upgrades all IIS scriptmaps to use the
2.0 release version of ASP.NET. After running this command and restarting
the server, the error message should no longer display.

Could not load <Global.app>

This error is usually due to an incorrect ASP.NET or IIS configuration
setup. To resolve this issue, make sure .NET Framework 2.0 is installed
on the server computer, register ASP.NET 2.0 with IIS by running aspnet_regiis.exe
-I
from the .NET Framework 2.0 directory, and
make sure ASP.NET 2.0 is the version set for your Web application
in the IIS Manager. You might also need to restart IIS.

Exception from HRESULT: 0x8007007E

This error can be caused by different versions of PowerBuilder
.NET assemblies in the server environment. To resolve this issue,
remove extra copies of PowerBuilder 12.0 .NET assemblies
from the Global Assembly Cache (GAC), leaving only the latest copies
of each assembly.

Page cannot be displayed

This error is also known as the �404 file not found� error.
If you see this error, make sure all the application files and folders have
been generated under the wwwroot directory on the IIS server computer. If
you are using a TCP port number other than 80 (the default port
number), you must include the port number in the URL for the Web
Forms application.

If you are trying to open the page from a remote client, ping
the server to make sure it is accessible. If the firewall is on
for the server you are accessing, turn it off and open the page
again.

File not found exception

After successfully deploying a Web Forms application, you
might see an error such as the following when you try to run the
application: System.IO.FileNotFoundException:
The specified module could not be found
. This
is typically because IIS cannot locate PowerBuilder runtime DLLs,
such as pbdwm120.dll or pbshr120.dll,
or the Microsoft Visual C++ runtime libraries msvcr71.dll and msvcp71.dll and
the Microsoft .NET Active Template Library (ATL) module, atl71.dll.
To resolve this issue, make sure the DLLs are available on the server
and that the directory where the DLLs are located is included in
the system path on the server.

Unexpected error was thrown

When a runtime JavaScript error occurs, the application terminates
and the following error message displays: �Unexpected error
was thrown, the browser will be closed!� Using a column
or field that has a JavaScript keyword for its name can cause this
type of error.


Document get from Powerbuilder help
Thank you for watching.
Was this article helpful?
Subscribe
Notify of
guest
0 Comments
Oldest
Newest Most Voted
Inline Feedbacks
View all comments
0
Would love your thoughts, please comment.x
()
x